PlanaOS-P-Flo flotation and filtration WWTP
PlanaOS-P-Flo industrial oil and oily wastewater treatment facilities are used to treat wastewater from industrial sites of oil and gas producing enterprises, refineries, energy and gas chemistry enterprises.
The basic purification technology is flotation followed by filtration.
- Cleaning to fish farm standards
- Block-modular design
- Maximum factory readiness
- Explosion and fireproof design (Ex)
- Compliance with industry standards
Constructions are carried out in a lightly prefabricated block or in a block-modular building equipped with all life support systems. Engineering and layout solutions provide convenient maintenance and access to equipment during maintenance and repair work.
* An example of a layout solution. The external storage tanks for raw effluent and the tank for clean/rinsing water are not shown conventionally.
PlanaOS-B-Flo installations can be made in a block-modular version for outdoor installation, or in a variant of installation in a production building.
Climatic version | UHL, HL1 (when placed outdoors) |
The material of the main structures | Steel 09G2S |
Enclosing structures | Three-layer sandwich panels 150…250 mm |
Process tanks and trays | stainless steel |
Technological pipelines | PVC /PP / Stainless Steel / Carbon Steel |
Performance | 1…15 l/s |
Number of lines | From 1 to 3 |
Runoff averaging | External storage tank |
Basic technologies | Oil recovery, reagent treatment, pressure flotation, mechanical and sorption filtration |
Disinfection of drains | UV disinfection |
Disposal of treated effluents | Under residual pressure / pressure |
Sludge dewatering | Screw-plate dehydrator |
Reservation | 100% hot reserve for drive equipment |
Automation | LSU based on a programmable logic controller |
Operator’s workplace | 15″ panel with mnemonic interface |
KIP interfaces | 4…20 mA, HART |
Interfaces with the Customer’s automated control system | RS 485 / Modbus RTU / Ethernet / Modbus TCP |
Additional | Spare parts, reagents and consumables for the period of the NDP |
The plants provide wastewater treatment up to the indicators given in the table.
Indicator, mg/dm3 | Input, max | Output, no more |
Suspended solids | 500 | 3 |
Petroleum products | 200 | 0.05 | pH | 7.0…11.0 | 7.0…8.5 |
The cost is determined by us in relation to your project, facility and wastewater quality.
At your request, we will provide a technical passport, a technological solution, a dimensional solution, bindings and loads, a commercial offer for the supply and provision of services.